Sprinkler O.T Tail PCN ( KP ) Specification

  • Connection Type
  • BSP Threaded
  • Sealing Type
  • O-ring Seal
  • Tolerance
  • 0.1 mm
  • Diameter
  • 15 mm
  • Thread Type
  • BSP Male
  • Yield Strength
  • 210 MPa
  • Tensile Strength
  • 520 MPa
  • Flexibility
  • Rigid
  • Bend Radius
  • Fixed
  • Temperature Range
  • -20C to +80C
  • Product Type
  • Sprinkler O.T Tail PCN
  • Material
  • Stainless Steel
  • Connection
  • Male Threaded
  • Shape
  • Round
  • Standard
  • IS 15105 / UL Listed
  • Surface Treatment
  • Polished
  • Outer Diameter
  • 15 mm
  • Section Shape
  • Cylindrical
  • Length
  • 150 mm
  • Thickness
  • 2 mm
  • Color
  • Silver
  • Usage
  • Fire Sprinkler System
  • Rated Pressure
  • 16 Bar
  • Material Grade
  • SS304
  • Application
  • Hospital Operation Theatre, Clean Room
  • Water Flow Capacity
  • Up to 68 LPM
  • Mounting Method
  • Ceiling Mounted
  • Corrosion Resistance
  • High
  • End Connection Size
  • 1/2 inch BSP
  • Packing Type
  • Box
  • Maintenance
  • Low Maintenance Required
  • Finish Type
  • Glossy
  • Operating Principle
  • Fusible Link
 
 

About Sprinkler O.T Tail PCN ( KP )

Providing you the best range of Agricultural HDPE Pipe Fittings  i.e. Adapter, EP Reducer Welded, Pipe Coupler, Tail Socket, Pipe Black Coupler and KP End Cap with effective & timely delivery

Engineered for Sensitive Environments

Designed specifically for hospital operation theatres and clean rooms, the Sprinkler O.T Tail PCN (KP) offers reliable fire protection without compromising hygiene or operational safety. Its stainless steel construction and polished finish not only enhance corrosion resistance but also provide an aesthetic appeal suitable for sterile settings.


Precision Manufacturing for Optimal Performance

Manufactured with a strict tolerance of 0.1 mm and using SS304 stainless steel, this ceiling-mounted sprinkler delivers consistent activation at rated pressures up to 16 bar. The polished, cylindrical design ensures optimal water distribution and ease of installation with BSP male threaded connections.

FAQ's of Sprinkler O.T Tail PCN ( KP ):


Q: How is the Sprinkler O.T Tail PCN (KP) installed in ceiling applications?

A: This sprinkler is designed for ceiling mounting using its BSP male threaded connection, simply securing into the compatible piping system. Installation should be performed as per IS 15105/UL standards to ensure optimal safety and performance.

Q: What are the key benefits of using this sprinkler in hospital operation theatres or clean rooms?

A: The sprinkler offers high corrosion resistance, low maintenance, and a hygienic, glossy polished finish, making it ideal for sterile environments like hospitals and clean rooms. Its reliable fusible link operating principle ensures quick response during a fire emergency.

Q: When should maintenance checks be performed, and what do they involve?

A: Regular visual inspection is recommended, though the sprinkler is designed for low maintenance. Maintenance mainly involves ensuring the outlet is free from obstruction and verifying the integrity of the O-ring seal for reliable sealing.

Q: Where can this sprinkler be used apart from hospitals and clean rooms?

A: While specifically designed for sensitive environments, the Sprinkler O.T Tail PCN (KP) can also be deployed in pharmaceutical areas, laboratories, or any other location requiring clean room standards and reliable fire suppression.

Q: What is the water flow capacity and how does it affect fire suppression?

A: With a water flow capacity up to 68 LPM and a rated pressure of 16 bar, this sprinkler can rapidly disperse water to control or suppress fires efficiently in its designated area.

Q: How does the fusible link operating principle work in this sprinkler?

A: The fusible link is a heat-activated component that ruptures or melts at a specific temperature, releasing the water flow to suppress fires. This mechanism ensures automatic operation without electrical power.

Q: What certifications and standards does the product comply with?

A: The Sprinkler O.T Tail PCN (KP) adheres to IS 15105 and is UL listed, ensuring compliance with international safety and performance standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pipes Fittings Category

Sprinkler Reducer Welded (KP)

Sprinkler Reducer Welded (KP)

Price 75 INR / Piece

Minimum Order Quantity : 10 Pieces

Flexibility : Rigid

Usage : Fire Sprinkler System

Connection : Other, Welded

Section Shape : Round

O.T Pcn ( EP )

O.T Pcn ( EP )

Price 80 INR / Piece

Minimum Order Quantity : 10 Pieces

Flexibility : Flexible

Usage : Electrical Panel Cable & Wire Management

Connection : Other, Push Fit

Section Shape : Other, Cylindrical

Sprinkler Y Bare

Sprinkler Y Bare

Price 20 INR / Piece

Minimum Order Quantity : 10 Pieces

Flexibility : Rigid

Usage : Agricultural/Industrial Irrigation

Connection : Other, Threaded

Section Shape : Other, Cylindrical

Sprinkler Reducer Welded ( EP )

Sprinkler Reducer Welded ( EP )

Price 100 INR / Piece

Minimum Order Quantity : 10 Pieces

Flexibility : Rigid

Usage : Fire Fighting System

Connection : Other, Welded

Section Shape : Round



Back to top